How do I set the input and output inteface Id? |
|
|
The netflow id corresponds to the SNMP interfaceId and not the nprobe interface id. In order to find the correct value, it is necessary to snmpwalk on the host where nprobe is active, and see what are the indexes associated with the interfaces. In other words it is necessary to make sure that the snmp interfaceId and netflow interfaceId are consistent.
Example: sh-3.2# snmpwalk -v 1 -c public localhost ifDescr IF-MIB::ifDescr.1 = STRING: lo0 IF-MIB::ifDescr.2 = STRING: gif0 IF-MIB::ifDescr.3 = STRING: stf0 IF-MIB::ifDescr.4 = STRING: en0 IF-MIB::ifDescr.5 = STRING: fw0 IF-MIB::ifDescr.6 = STRING: en1 IF-MIB::ifDescr.7 = STRING: en2 IF-MIB::ifDescr.8 = STRING: en3 This means that we need to use interfaceId 8 for en3, 7 for en2.... Note that some collectors do not like flows with the same input and output interfaceId, so in case you use the same Id for in and out, this can create problems. |
|